The device operates with an input voltage range of 100–270V at 50/60Hz and includes line OVP and UVP protection. It is designed to withstand lightning surges of 2KV/4KV between power lines and 4KV between line and earth. For electrostatic discharge, it supports 6KV contact discharge and 10KV air discharge. With an efficiency level of V, its power consumption at no load is just 0.3W maximum. The operating temperature range is 0°C to 50°C. Built-in protections include OVP, UVP, OCP, SCP, and OPP. Certified by BIS (Wisepower), the unit does not include an LED indicator option. It is suitable for IT and AV equipment such as routers, set-top boxes, gateways, and speakers.