| Item/Model |
DC Dual Charging Control Board |
| Power Supply (POWER) |
DC12V±0.5V 2A |
| Swipe Card Board 232 |
Card reader, RS232 communication, external IC non-contact card reader for card charging and settlement |
| Display 232 |
Touch screen RS232 communication, compatible with 4.3-inch and 7-inch screens, customizable |
| LED Indicators |
Standby, charging, and fault lights (Blue: standby, Green flashing: charging, Red: fault) |
| A-gun Auxiliary Power Supply 12V (DO1) |
Controls BMS-12V power of gun A, normally open |
| A-gun Auxiliary Power Supply 24V (DO2) |
Controls BMS-24V power of gun A, normally open |
| B-gun Auxiliary Power Supply 12V (DO3) |
Controls BMS-12V power of gun B, normally open |
| B-gun Auxiliary Power Supply 24V (DO4) |
Controls BMS-24V power of gun B, normally open |
| AC Contactor (DO5) |
Controls AC main input contactor, normally open |
| A-gun DC Contactor (DO6) |
Controls A-gun DC output contactor, normally open |
| B-gun DC Contactor (DO7) |
Controls B-gun DC output contactor, normally open |
| Switching DC Contactor (DO8) |
Controls DC output contactor switching between A and B guns for fixed/flexible stations |
| Cooling Fan (DO9) |
Controls cooling fan of the charging station, normally on |
| Switching DC Contactor 2 (DO10) |
For flexible piles (3/4 modules), controls switching to B-gun or module outputs |
| Switching DC Contactor 3 (DO11) |
For 4-module flexible pile, controls module 2 switching to B-gun output |
| Emergency Stop Detection (DI1) |
Emergency stop button status detection |
| Threshold Detection (DI2) |
Cabinet door open/close detection |
| Communication Contactor Feedback (DI3) |
AC input contactor status detection |
| Lightning Protection Detection (DI4) |
Detects working status of lightning arresters |
| A-gun Electronic Lock Feedback (DI5) |
Lock/unlock status detection of gun A |
| B-gun Electronic Lock Feedback (DI6) |
Lock/unlock status detection of gun B |
| A-gun DC Contactor Feedback (DI7) |
A-gun DC contactor suction status detection |
| B-gun DC Contactor Feedback (DI8) |
B-gun DC contactor suction status detection |
| Switching DC Contactor Feedback (DI9) |
Switching DC contactor status detection |
| Backup (DI10) |
Backup detection input port |
| Working Temperature |
-20°C ~ 60°C |
| Storage Temperature |
-40°C ~ 85°C |
| Bare Board Installation Dimension |
186mm × 106mm |